HS35: Auto & Manual Ranging Stick MultiMeter Kit
CODE: HS35
HS35: Expandable Digital Multimeter
The Perfect Fit for HVAC-R
- Works with any accessory head
- Non-contact voltage - Built-In Volt Stick
- Microamps DC for flame diodes
- 400 AAC with included Clamp Accessory
- Temperature up to 535 degrees C
- Convenient lead storage
- Safe one-handed testing
The HS35 manual and auto ranging multimeter includes the tests you use everyday for HVACR field service. Like the rest of the HS30 series, the HS35 works with all of our accessory heads. It comes equipped with a magnetic hanger, detachable silicone test leads and alligator clip probe tips for remote and easy one-handed testing, as well as the full set of built-in safety features. Built-in temperature with excellent compensation and capacitance ranges are a big plus.
The removable tip test leads and alligator probe extensions make safe one-handed testing a snap. The k-type thermocouple port on the front of the meter allows you to test a number of HVAC parameters right from your multimeter. And it's packed with the features HVACR professionals need:
- High Voltage and Continuity Indicators
- Microamps
- Capacitance
- MIN/MAX
- Temperature
- Rugged ABS case with rubberized bumpers
- Built-in magnetic hanger allows you to test with one hand or no-hands
- Built-in lead storage
- Ergonomic shape fits naturally in your hand
- Auto power-off (APO) to conserve battery life
(HS35)
What's Included
- Expandable Auto Ranging Stick Multimeter - HS35
- 400A Amp Clamp Accessory - ACH4
- Deluxe Silicone Test Leads - ADLS2
- Short Alligator Lead Extensions - ASA2
- Deluxe Meter Case - ANC1
- 9-Volt Battery (installed)
- Operator’s Manual
Download the full Operators Manual
SPECIFICATIONS
- Display: 3¾ digit liquid crystal display (LCD) with a maximum reading of 3999.
- Analog bar graph: 41 segments with measurements 20 times per second.
- Range (RNG): Manual ranging mode (HS35) Overrange: "OL" mark indication.
- Auto power off: 30 minutes.
Operating environment: 32°F to 122°F at <70% R.H.
- Storage temperature: -4°F to 140°F, 0 to 80% R.H. with battery removed.
Accuracy:
- Specifications good in ambient conditions of 73°F ±9°F, <75% relative humidity.
- Temperature coefficient: 0.1×(specified accuracy) per °F. (32°F to 64°F, 82°F to 122°F).
- Power: Single standard 9-volt battery, NEDA 1604, JIS 006P, IEC 6F22.
- Battery life: 300 hours typical with alkaline.
- Accessories: One pair test leads, one pair alligator clips, k-type thermocouple, 9V battery (installed), and operating instructions.
- Safety: UL, CE, Cat III 600V, UL3111, IEC1010-1.
- Temperature Range: -30°F ~ 1000°F Resolution: 0.1°F Accuracy: ±(1°F) 32°F ~ 120°F, ±(1% + 1.5°F) -4°F ~750°F, ±(2% + 4°F) -30°F ~ -4°F, ±(2% + 4°F) 750°F ~ 1000°F
- Sensor type: K-type thermocouple
- Overload protection: 60 VDC or 30 VAC rms
- Continuity Audible indication: Less than 40Ω Response time: 500ms Green LED will be on continuously.
- Overload protection: 500VDC or AC rms
DC volts Ranges: 400mV, 4000mV, 40V, 400V, 600V
- Resolution: 0.1mV Accuracy: ±(0.5% rdg + 2 dgt)
- Input impedance: 560kΩ on V inputs, 10MΩ on mV input
- Overload protection: 600VDC or AC rms
- Transient protection: 6kV for 10µ sec
AC volts (50Hz - 500Hz) Ranges: 400mV, 4V, 40V, 400V, 600V
- Conversion: True RMS (HS36), average (HS35)
- Crest factor: Less than or equal to 3 (HS36)
- Resolution: 0.1mV Accuracy: ±(1.2% rdg + 5 dgts) 50Hz ~ 60Hz on 400mV range ±(1.5% rdg + 5 dgts) ±(2% rdg + 5 dgts) on 600V range
- Input impedance: 560kΩ
- Overload protection: 600V DC or AC rms
- Transient protection: 6kV for 10µ sec
DC current Ranges: 400µA, 4000µA Resolution: 0.1µA
- Accuracy: ±(1.0% rdg + 2 dgt) Voltage burden: 200mV, (2V on 4000µA range)
- Input protection: 250mA/600V (6.3×32 mm fast blow ceramic fuse), part number RFM66
Resistance Ranges: 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ
- Resolution: 0.1Ω Accuracy: ±(1.0% rdg + 4 dgts) on 400Ω to 400kΩ ranges ±(1.5% rdg + 4 dgts) on 4MΩ range ±(3.0% rdg + 5 dgts) on 40MΩ range
- Open circuit volts: -0.45VDC typical, (-1.2VDC on 400Ω range)
- Overload protection: 500VDC or AC rms
Capacitance Range: 400µF Resolution: 0.1µF
- Accuracy: ±(3% rdg + 5 dgts)
- Input protection: 250mA/600V (6.3×32 mm fast blow ceramic fuse), part number RFM66
Frequency Ranges: 4k, 40k, 400k, 4M, 40MHz
- Resolution: 1Hz Accuracy: ±(0.1% rdg + 3 dgts)
- Sensitivity: 10Hz ~ 4MHz: > 1Vrms, 4MHz ~ 40MHz: > 2Vrms, <5Vrms
- Minimum pulse width: > 25ns Duty cycle limits: > 30% and < 70%
- Overload protection: 500VDC or AC rms
SKU | HS35 |
Brand | Fieldpiece |
Shipping Weight | 1.5000kg |
Shipping Width | 0.200m |
Shipping Height | 0.100m |
Shipping Length | 0.350m |
Shipping Cubic | 0.007000000m3 |
Unit Of Measure | ea |
Assembled Length | 0.350m |
Assembled Height | 0.100m |
Assembled Width | 0.200m |
Be The First To Review This Product!